The system over strength factor Ω0 is used as a multiplier on the load
side of the equation.
For example, in a braced-frame system, it is
applied as a multiplier on the axial load in the brace. The resulting
amplified force is used to compare to each applicable limit state
Answered by
Haseeb Jamal
at
May 30, 2010 09:58 PM